Communication Manager Maintenance-Object Repair Procedures
832 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1004 ABRT The test was aborted because the port was seized by a user for a valid
call.
1. Use display port location to determine the trunk group/
member number of the port. Use status trunk to determine the
service state of the port. If the port is active, wait until it is idle before
testing.
2. If the port status is idle, retry the command at 1-minute intervals up to
5 times.
1005 ABRT Test failed due to incompatible configuration administered in trunk group
screen.
1. Look at the trunk group administration form and see whether the trunk
is incoming only, port 24 on a DS1 Interface with common control
channel signaling, or an automatic CO type such as FX. Under any of
these conditions this is a normal abort.
1018 ABRT Test is disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Group
screen is n. To enable the test, enter change trunk-group <x>
(<x> is the number of the trunk group to be tested). Change the
Maintenance Test field on the screen to y.
2. Repeat the test.
1020 ABRT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log. If
present, see the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Trunk
circuit pack).
2. Retry the command.
1040 ABRT The test was aborted because this port may be an access endpoint.
1. Verify that this port is an access endpoint by issuing display port
location
2. If the port has been administered as an access endpoint, then this is a
normal abort.
Table 285: Test #314 DS1 CO Dial Tone Seizure Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 4