Avaya 03-300430 Home Security System User Manual


  Open as PDF
of 2574
 
XXX-BD (Common Port Circuit Pack/Media Module)
Issue 1 June 2005 2551
Control Channel Loop-Around Test (#52)
This test queries the circuit pack or media module for its code and vintage, and verifies its
records.
Table 911: Test #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The test failed because the circuit pack or media module failed to return
the code or vintage.
1. Retry the command up to 5 times.
2. If the test still fails, enter busyout board location, reset
board location, and release board location, and then
retest.
3. If the problem continues, replace the circuit pack or media module.
4. Run the test again.
PASS Communication with this circuit pack or media module is successful.
The next test result is for systems supporting circuit packs only.
S8700 |
8710
/
S8500
EXTRA
BD
This result should only appear when more than one TN771D
Maintenance/Test circuit pack has been installed in this port network.
Remove this circuit pack.
S8700 |
8710
/
S8500 /
Any
NO
BOARD
This is normal if the test is being done when (a) the board is not
physically in the system or (b) the system is booting up. Otherwise,
there is some inconsistency between the physical configuration and the
data kept in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals up to 5 times.