Communication Manager Maintenance-Object Repair Procedures
746 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
d. Error Type 769—This error indicates that a message with a valid op-code was received but
some other part of the message was indecipherable. The op-code with the error is recorded
under Aux data.
e. Error Type 1025—This error indicates that an unsuccessful attempt was made to reset
environmental maintenance.
f. Error Type 1281—This error indicates that environmental initialization failed. Run the
Reset
Environmental Maintenance Test
(#1545), which calls the Initialization Test (#1548).
System technician-demanded tests:
Descriptions and error codes
Investigate tests in the order presented. When you clear error codes associated with the
Correct Board Test (1546), you might also clear errors generated from other tests in the testing
sequence.
Reset Environmental Maintenance test (#1545)
This test resets the environmental maintenance on the TN2312BP IPSI board.
Order of investigation Short test
sequence
Long test
sequence
D/ND
1
1. D = Destructive, ND = Nondestructive
Correct Board Test (#1546) X X ND
Sanity Test (#1547) X X ND
Reset Environmental Maintenance Test (#1545) — X D
Table 254: Test #1545 Reset test
Error
code
Test
result
Description and recommendation
1000 ABRT There is an internal software problem.
1. Repeat the command at one-minute intervals 1 to 3 times.
1 of 2