OPS-LINE (DS1 Off-Premises Station Line)
Issue 1 June 2005 1749
2000 ABRT The test was aborted because response to the test was not received
within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test aborts with Error Code 2000 again, run short test
sequence on the associated DS1-BD or UDS1-BD. If tests 138
through 145 on the associated DS1-BD or UDS1-BD are also
aborting with Error Code 2000, hyperactivity on the board or facility
is indicated. In this case, the hyperactivity problem should be dealt
with first.
2012 ABRT The test was aborted due to a system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABRT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1 FAIL Internal system error.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log. If
present, see DS1-BD (DS1 Interface Circuit Pack)
on page 978.
2. If a channel multiplexer is used as the remote DS1 endpoint to
which the station connects, refer to the multiplexer vendor’s
maintenance document for diagnosis.
3. Retry the command at 1-minute intervals up to 5 times.
PASS The station hook states in both switch software and DS1 Interface circuit
pack are consistent.
Table 647: Test #312 DS1 OPS Switchhook Inquiry Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 3