Communication Manager Maintenance-Object Repair Procedures
2548 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
NPE Audit Test (#50)
Note:
Note: G700: On the G700/G350, this test aborts with Error Code 1412.
The system sends a message to the on-board microprocessor to update the network
connectivity translation for every NPE (Network Processing Element) on the circuit pack.
Table 909: Test #50 NPE Audit Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1019 ABRT Test already in progress.
G700:
1412
ABRT This test does not execute on a G700 Media Gateway.
FAIL Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS The circuit pack’s NPEs have been updated with their translation.
EXTRA
BD
Certain circuit packs have limitations on how many circuit packs can be in
the system or port network such as the Maintenance/Test circuit pack
(TN771B or TN771C), the Tone Detector circuit pack (TN748B, TN748C or
TN748D) and the Call Classifier (TN744). The Maintenance/Test circuit
pack allows only one circuit pack per port network. The Tone Detector and
Call Classifier allow only 10 circuit packs in each system. All additional
circuit packs will return EXTRA-BD and should be removed.
Any NO
BOARD
This is normal if the test is being done when: (a) the board is not
physically in the system or (b) the system is booting up. Otherwise, there
is some inconsistency between the physical configuration and the data
kept in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at 1-minute intervals up to 5 times.