EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 June 2005 1225
Table 416: Test #589 Expansion Interface Packet Interface Test
Error
Code
Test
Result
Description / Recommendation
1033 ABRT The test cannot run because the EI circuit pack does not have a fiber link
administered to it and there is not sufficient data to run the test or because
EI circuit packs on other port networks needed for this test are out of
service.
1. Execute list fiber-link and determine whether the EI circuit pack
under test is an endpoint of one of the administered fiber links. If so,
then proceed to step 2. If not, then this is considered to be a spare
board, and the test should not be attempted on this EI circuit pack.
2. Follow procedures for applicable configuration:
Direct Connect:
1. Use list config for the cabinet and carrier where the neighbor EI
circuit pack resides. If the results reveal that the board is not
recognized by software, the board is out of service because of this
condition. Perform the following steps:
a. If this test is being executed on an EI circuit pack located in the PN,
enter display errors and resolve any EXP-PN errors for the port
network where the neighbor EI circuit pack resides. Re-execute this
test.
b. If this test continues to abort with this abort code reset the DS1
converter circuit pack (if so equipped) or the neighbor EI circuit pack.
This will not be destructive since the circuit pack cannot be serving
as the Expansion Archangel if it is not in service.
2. Run Test #237 and check for EXP-INTF circuit pack Error Type 1281 in
the Error Log. If Error Type 1281 is present and/or Test #237 does not
pass, see repair procedures for Test #237, in Table 409: Test #237
Expansion Interface Neighbor Query Test on page 1199.
3. If Test #237 passes, reseat the EI circuit pack. This will not be
destructive since the circuit pack cannot be serving as the Expansion
Archangel if it is not in service.
4. Repeat Test #237.
1 of 5