BRI-PORT (ISDN-BRI Port)
Issue 1 June 2005 685
BRI-PORT (ISDN-BRI Port)
Error log entries and tests also apply to ABRI-POR, ATT-PORT, LGATE-PT, and ATTE-PT.
S8700 | 8710 / S8500
Note:
Note: Some of the information in this section is reserved for future use.
!
CAUTION:
CAUTION: The section, Isolating and repairing packet-bus faults in Maintenance Procedures
(03-300192), along with the other information presented in the chapter, can help
resolve problems involving more than one station or circuit pack.
!
WARNING:
WARNING: If a significant packet-bus failure occurs, errors and alarms may not be logged as
expected for BRI-PORT/ABRI-POR/ATT-PORT/ LGATE-PT/ ATTE-PT.
Conditions under which this occurs are detailed in Isolating and repairing
packet-bus faults in Maintenance Procedures (03-300192).
MO Name in
Alarm Log
Alarm
Level
Initial Command to Run Full Name of MO
BRI-PORT MIN test port location l ISDN-BRI port
BRI-PORT WRN test port location sh ISDN-BRI port
ABRI-POR MAJ
1
1. The alarm level for ASAI and Avaya adjunct ports may be administered using set options. The alarm level
can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for every ASAI
and Avaya adjunct port in the system.
All alarming for an ASAI and Avaya adjunct and OFF-BOARD alarming for an ASAI or Avaya port is
disabled if the ASAI or Avaya adjunct asks the switch to suspend maintenance. When this occurs, an error
and a WARNING alarm is logged against the ASAI or Avaya adjunct. The Hardware Error and Alarm Logs
should be checked to see if the adjunct has disabled alarming.
test port location l ASAI ISDN-BRI port
ABRI-POR WRN1
test port location l ASAI ISDN-BRI port
ATT-PORT MAJ 1
test port location l Avaya Adjunct ISDN-BRI port
ATT-PORT WRN 1
test port location l Avaya Adjunct ISDN-BRI port
LGATE-PT MAJ 1
test port location l Ethernet ASAI port
LGATE-PT WRN 1
test port location l Ethernet ASAI port
ATTE-PT MAJ 1
test port location l Ethernet Avaya Adjunct port
ATTE-PT WRN 1
test port location l Ethernet Avaya Adjunct port