Communication Manager Maintenance-Object Repair Procedures
2232 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
1024 ABRT (M/T-DIG) Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the M/T-BD
(Maintenance/Test circuit pack).
2. Retry the test. If problem persists, see M/T-DIG (Maintenance/
Test Digital Port) on page 1709.
1113 ABRT The signaling link has failed; the system cannot send any messages
on behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State Check
Test).
1114 ABRT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
1116 ABRT The switch could not appropriately change the ISDN service state.
1. Enter status trunk to determine whether a call is active on
this trunk-side ISDN-BRI channel.
2. If not, check the error and alarm logs for problems with this
TBRI-TRK MO.
1117 ABRT ISDN B-channel maintenance message is already outstanding.
1. Wait two minutes, then try again.
1118 ABRT Far end of ISDN trunk is not administered.
1. Check the administration of the far-end ISDN trunk.
2. Enter status trunk, and try the test again.
1119 ABRT The test call was aborted due to a normal call attempt on this trunk.
The test call is performed only if the trunk is idle.
1. Either wait for the normal call to terminate normally, or force it to
be dropped by using busyout trunk.
Table 800: Test #258 ISDN Test Call (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 6