EXT-DEV (External device alarm)
Issue 1 June 2005 1241
System technician-demanded test:
Descriptions and error codes
Alarm query test
(#120)
The external device alarm test requests the status of the external device alarm from a
maintenance circuit pack and reports the results. The test has no affect on the external device
itself. The test environment command will report an error against Test #120 if there is a
short on one or both of the pairs of leads connecting the external device.
!
CAUTION:
CAUTION: Alarms can be generated on adjunct equipment, sent to the Avaya system, and
recorded and reported as "external alarms". The adjunct equipment must provide
an isolated contact closure across the alarm leads provided by the Avaya system.
The contact must be rated at a minimum of 60 V DC, with a current carrying
capacity of 5 mA minimum.
Order of investigation Short test
sequence
Long test
sequence
D/ND
Alarm query test (#120) X X Nondestructive
Table 423: Test #120 Alarm query
Error
code
Test
result
Description and Recommendation
1000 ABRT This is an internal system error.
1. Repeat the command at one-minute intervals 1 to 3 times.
1035 ABRT The port network is not available.
1. Use status port-network to verify that the network is not up.
2. Look for alarms against EXP-PN, EXP-INT, PK-INT, etc.
3. Use diagnostic procedures for those MOs to clear the problem.
2000 ABRT A response to the test request was not received within the time allowed.
1. Repeat the command at one-minute intervals 1 to 3 times.