Communication Manager Maintenance-Object Repair Procedures
1864 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Notes:
a. Error Type 0: an error took place in generating the Error Code.
b. Error Type 10000-10063: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the A-PNC associated with fault class FC_EAL. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (10003 points to port network 4) Use list config
port-network to show the cabinet number associated with a port network.
c. Error Type 10100-10163: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the A-PNC associated with fault class FC_INL. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (10003 points to port network 4)Use list config
port-network to show the cabinet number associated with a port network.
d. Error Type 10200-10263: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the A-PNC associated with fault class FC_HW. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (10203 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.
e. Error Type 10300-10363: a spontaneous PNC interchange took place in response to the
retiring of an alarm on the A-PNC associated with fault class FC_PER. Use status pnc to
look at the state of health indexes for the PNCs, and investigate any associated alarms.
Adding 1 to the last two digits of the Error Code gives the PN number of the port network
that reported the retired alarm. (10303 points to port network 4.) Use list config
port-network to show the cabinet number associated with a port network.
11701 – 11764 (p
)
1
53000 (ah)
1
20000 – 20063 (q)
1
60801 (ai)
1
20100 – 20163 (r)
1
60800 (aj)
1
1. The Aux Data indicates which PNC became active after the PNC interchange: “0”
denotes PNC-A; “1” denotes PNC-B.
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
18 None busyout pnc-dup WRN ON release pnc-dup
Error Type Aux Data Error Code Aux Data
2 of 2