Communication Manager Maintenance-Object Repair Procedures
2400 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
Control Channel Loop-Around Test (#52)
This test queries the circuit pack for its code and vintage and verifies its records.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Execute add ds1
location to administer the UDS1 interface if it is not already
administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the
board is shut down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter
busyout board location
4. Enter reset board location
5. Enter release board location
6. Enter test board location long
This should re-establish the linkage between the internal ID and the port.
Table 854: Test #50 NPE Connection Audit Test (continued)
Error
Code
Test
Result
Description / Recommendation
2 of 2
Table 855: Test #52 Control Channel Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
None
2100
ABRT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The circuit pack failed to return the its code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues and if the circuit pack is a port circuit pack,
replace the circuit pack.
3. Retry the command several times up to 5 times.