DAT-LINE (Data Line Port)
Issue 1 June 2005 871
Notes:
a. Error Type 0
: Run the short test sequence first. If every test passes, run the long test
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 15: This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate errors.
c. Error Type 130: the circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, reseat or replace the circuit pack.
d. Error Type 769: the data line circuit pack found an error in the transmit/receive circuitry of
an administered data line when the circuit pack was inserted. Perform the following:
1. Enter busyout board location for the circuit pack on which the port resides.
2. Enter reset board location. Check the Error Log to determine whether Error Type
#769 is logged again for DAT-LINE. Verify that the Active Alarms Only field is n.
If Error Type #769 reappears, replace the data line circuit pack. If not, proceed to Step 3.
3. Enter release board location.
15(b
) Any Audit Update test
(#36)
18 0 busyout port
location
WRN OFF rel port location
130 (c
) None WRN ON test port location sh
257 Conference
Circuit test (#7)
MIN ON test port location l r 2
513 NPE Crosstalk
test (#6)
MIN ON test port location l r 2
769(d
) 40983 None
Table 296: Data Line Port Error Log Entries (continued)
Error
Type
Aux
Data
Associated Test Alarm
Level
On/Off
Board
Test to Clear Value
2 of 2