3. Control Panel Orientation
Control Panel Descriptions
~ DSK Source — (directly above the DSK button), indicates the current
source assigned to the downstream keyer. When you select another
source on the Phantom Key Bus, the source label updates.
~ Current Transition Rate — indicates the auto-transition rate loaded in
the PGM bank. This rate is used by the AUTO TRAN and DSK
functions. Use the Transition Menu to change rates. In Chapter 5, see
the “Transition Menu
” section on page 148 for details.
~ Current Fade to Black Rate — indicates the auto-transition rate for the
fade to black (FTB) function. Use the Transition Menu to change rates.
2) T-Bar and Transition LEDs
The T-Bar provides manual transition control for the layers enabled in the Next
Transition Group. For both manual and automatic transitions, the Transition
LEDs always indicate the position of the transition in progress.
Figure 3-8. T-Bar and Transition LEDs
T-Bar functionality is identical for both the M/E bank and the PGM bank. In
Chapter 7, refer to the “Understanding the T-Bar and Transition LEDs
” section
on page 325 for complete details.
3) Next Transition Group
The two buttons in the Next Transition Group indicate which specific
combination of layers is armed for the next transition. The state of these buttons
affects the bank’s “lookahead” preview output.
Figure 3-9. Next Transition Group
To use the group, simultaneously press the combination of buttons that you wish
to enable. Any combination can be pressed. Whichever combination you enable
automatic disables those buttons that were not pressed.
Note
If a DVE is assigned to the DSK, and the DVE is enabled
(either in PIP or KEY mode), this label indicates the source
routed to the DVE — in other words, the DVE’s input. DVE
assignment status is listed on the DVE Assign Menu.
In Chapter 8, refer to the “DVE Assign Menu
” section on
page 363 for details.
T-Bar
Transition
LEDs
BG DSK