16 - 59
Chapter 16 Troubleshooting
Related buffer memory address
Set range
(Setting with sequence program)
Remedy
QD77MS2
QD77MS4
QD77MS16
54003+20k
< Mark detection data axis No.>
1 to 16, 801 to 804
Set a value within the setting range.
54004+20k
54005+20k
<Mark detection data buffer memory No.>
0 to 65534
Set a value with an even number within the setting
range.
JOG speed
<JOG speed>
1 to 1000000000 [PLS/s]
1 to 2000000000 [
10
-2
mm/min or another]
Do not carry out the JOG speed change during
deceleration with the JOG start signal OFF.
1518+100n
1519+100n
4318+100n
4319+100n
New speed value
<New speed value>
0 to 1000000000 [PLS/s]
0 to 2000000000 [
10
-2
mm/min or another]
Set a value within the setting range.
1514+100n
1515+100n
4314+100n
4315+100n
JOG speed limit value
<JOG speed limit value>
1 to 1000000000 [PLS/s]
1 to 2000000000 [
10
-2
mm/min or another]
48+150n
49+150n
Positioning operation speed override
< Positioning operation speed override >
1 to 300 [%]
1513+100n 4313+100n
1522+100n
1523+100n
4322+100n
4323+100n
<Manual pulse generator 1 pulse input
magnification>
1 to 1000
Set the manual pulse generator 1 pulse input
magnification to within the setting range.
n: Axis No.-1
k: Mark detection setting No.-1