Appendix - 77
Appendices
Setting item
Default
value
Setting
value
Details
[Pr.75]
Reset selection/
disconnected PU
detection/
PU stop selection
14
0
• Reset input is always enabled.
• If the PU is disconnected, operation will be continued.
• PU stop is disabled at SSCNET connection.
1
• A reset can be input only when the protective function is activated.
• If the PU is disconnected, operation will be continued.
• PU stop is disabled at SSCNET
connection.
2
• Reset input is always enabled.
• When the PU is disconnected, the inverter trips.
• PU stop is disabled at SSCNET
connection.
3
• A reset can be input only when the protective function is activated.
• When the PU is disconnected, the inverter trips.
• PU stop is disabled at SSCNET
connection.
14
• Reset input is always enabled.
• If the PU is disconnected, operation will be continued.
• Deceleration stop by PU stop in any operation mode.
15
• A reset can be input only when the protective function is activated.
• If the PU is disconnected, operation will be continued.
• Deceleration stop by PU stop in any operation mode.
16
• Reset input is always enabled.
• When the PU is disconnected, the inverter trips.
• Deceleration stop by PU stop in any operation mode.
17
• A reset can be input only when the protective function is activated.
• When the PU is disconnected, the inverter trips.
• Deceleration stop by PU stop in any operation mode.
(Note): Note that the default value is set to "14". (Change the value to "1 to 3".)
(5) In-position range
Set the servo parameter "In-position range (PA10)" and the parameter of the
inverter "[Pr.426] In-position width" to be matched. Otherwise, it may not
operate correctly.
Setting item
Default
value
Setting range
Buffer memory address
QD77MS2
QD77MS4
QD77MS16
PA10
In-position
range
100
(PLS)
0 to 65535
(PLS)
30110+200n 28410+100n
n: Axis No.-1
Setting item
Default
value
Setting range Details
[Pr.426]
In-position
width
100
(PLS)
0 to 32767
(PLS)
When droop pulses have fallen
below the setting value, the in-
position signal turns ON.