14 - 3
Chapter 14 Common Functions
Common function Details
Means
Sequence
program
GX Works2
Module error collection function
This function collects errors occurred in the Simple
Motion module in the PLC CPU.
Holding the error contents in the PLC CPU, this
function enables to check the error history even after
the PLC CPU in powered off or reset.
—
Connect/disconnect function of
SSCNET communication
Temporarily connect/disconnect of SSCNET
communication is executed during system's power
supply ON.
This function is used to exchange the servo
amplifiers or SSCNET
cables.
—
QD75MH initial value setting
function
This function is used to set the factory-set initial
value of QD75MH in the setting data set in the
QD77MS buffer memory/internal memory and flash
ROM/internal memory (nonvolatile).
—
Hot line forced stop function
This function is used to execute deceleration stop
safety for other axes when the servo alarm occurs
in the servo amplifier MR-JE-B.