Mitsubishi Electronics QD77MS2 Home Security System User Manual


  Open as PDF
of 1038
 
13 - 67
Chapter 13 Control Sub Functions
13.7 Other functions
Other functions include the "step function", "skip function", "M code output function",
"teaching function", "command in-position function", "acceleration/deceleration
processing function", "pre-reading start function", "deceleration start flag function",
"stop command processing for deceleration stop function", "follow up processing
function", "speed control 10
multiplier setting for degree axis function" and
"operation setting for incompletion of OPR function". Each function is executed by
parameter setting or sequence program creation and writing.
13.7.1 Step function
The "step function" is used to confirm each operation of the positioning control one by
one.
It is used in debugging work for major positioning control, etc.
A positioning operation in which a "step function" is used is called a "step operation".
In step operations, the timing for stopping the control can be set. (This is called the
"step mode".) Control stopped by a step operation can be continued by setting "step
continues (to continue the control)" in the "step start information".
The details shown below explain about the "step function".
[1] Relation between the step function and various controls
[2] Step mode
[3] Step start information
[4] Using the step operation
[5] Control details
[6] Precautions during control
[7] Step function settings
[1] Relation between the step function and various controls
The following table shows the relation between the "step function" and various
controls.
Control type Step function Step applicability
OPR control
Machine OPR control
Step operation not possible
Fast OPR control
Major positioning
control
Position
control
1-axis linear control
Step operation possible
2 to 4-axes linear interpolation control
1-axis fixed-feed control
2 to 4- axes fixed-feed control
(interpolation)
2-axis circular interpolation control
1 to 4- axes Speed control Step operation not possible
Speed-position switching control
Position-speed switching control
Step operation possible
Other
control
Current value changing
JUMP instruction, NOP instruction,
LOOP to LEND
Step operation not possible
Manual control
JOG operation, Inching operation
Step operation not possible
Manual pulse generator operation
Expansion
control
Speed-torque control
: Set when required, : Setting not possible