5 - 169
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
QD77MS2
QD77MS4
QD77MS16
Set with a decimal.
K
1
M code OFF request
Setting value
A
fter the M code ON signal turns OFF, "0" is stored by the Simple Motion
module automaticall
y
.
(
Indicates that the OFF request is completed.
)
1: M code ON signal turns OFF
0 1504+100n 4304+100n
Set with a decimal.
Setting value
External command valid
0: Invalidates an external command.
1: Validates an external command.
K
0 1505+100n 4305+100n
Set with a decimal.
A
ctual value
Conversion into an integer value
Cd.9 New current value
10
m
Unit conversion table ( Cd.9 )
m
1
5
5
0
inch
degree
PLS
Unit
R
Setting value
(Decimal)
m
0
1506+100n
1507+100n
4306+100n
4307+100n
Set with a decimal.
Cd.10 New acceleration time value
Cd.11 New deceleration time value
Setting
value
Example: When the " Cd. 10 New acceleration
time value" is set as "60000 ms", the
buffer memory stores "60000".
0
1508+100n
1509+100n
4308+100n
4309+100n
0
1510+100n
1511+100n
4310+100n
4311+100n
n: Axis No.-1