5 - 58
Chapter 5 Data Used for Positioning Control
[Pr.47] Creep speed
Set the creep speed after near-point dog ON (the low speed just before stopping
after decelerating from the OPR speed).
The creep speed is set within the following range.
([Pr.46] OPR speed) ([Pr.47] Creep speed) ([Pr.7] Bias speed at start)
ON
V
Machine OPR
start
Near-point
dog signal OFF
Zero signal
OPR speed
Pr.46
Creep speedPr.47
[Pr.1] setting value
Value set with GX Works2
(unit)
Value set with sequence program
(unit)
0 : mm 0.01 to 20000000.00 (mm/min)
1 to 2000000000 (
10
-2
mm/min)
1 : inch 0.001 to 2000000.000 (inch/min)
1 to 2000000000 (
10
-3
inch/min)
2 : degree
0.001 to 2000000.000 (degree/min)
1
1 to 2000000000 (
10
-3
degree/min)
2
3 : PLS 1 to 1000000000 (PLS/s) 1 to 1000000000 (PLS/s)
1: The range of home position return speed when "[Pr.83] Speed control 10 x multiplier setting for
degree axis" is valid: 0.01 to 20000000.00 (degree/min)
2: The range of home position return speed when "[Pr.83] Speed control 10 x multiplier setting for
degree axis" is valid: 1 to 2000000000 (
10
-2
degree/min)