14 - 24
Chapter 14 Common Functions
(8) Even if the PLC READY signal [Y0| is turned ON by changing "[Pr.100]
Servo series" from "0: Servo series is not set" to other than "0", the setting
does not become valid. (The axis connecting status remains disconnection.)
(9) The operation cannot be changed to amplifier-less operation when
connected and not connected servo amplifier axes are mixed. Change to
amplifier-less operation when all axes are connected, or disconnect all
axes of the servo amplifier.
(10) The synchronous encoder via servo amplifier cannot be used during
amplifier-less operation mode.
[3] Buffer memory list
The buffer memory used in the amplifier-less operation function is shown below.
(1) System control data
Setting item
Setting
value
Setting details
Buffer memory address
QD77MS2
QD77MS4
QD77MS16
[Cd.137]
Amplifier-less
operation mode
switching request
Switch operation mode.
ABCDh : Switch from the normal operation
mode to the amplifier-less operation
mode.
0000h : Switch from the amplifier-less
operation mode to the normal
operation mode
1926 5926
(2) System monitor data
Monitor item
Monitor
value
Storage details
Buffer memory address
QD77MS2
QD77MS4
QD77MS16
[Md.51]
Amplifier-less
operation mode
status
Indicate the current operation mode.
0: Normal operation mode
1: Amplifier-less operation mode
1432 4232