Appendix - 84
Appendices
(2) Warning
When a warning occurs on FR-A700 series, the warning code (61696 to
61951) is stored in "[Md.24] Axis warning No.".
The warning No. of FR-A700 series is stored in "[Md.58] Servo warning" in
warning history.
The detection warning list for FR-A700 series is shown below.
Classification
of warnings
Warning code
Warning No. of
FR-A700 series
FR-A700 series
LED display
Name Remarks
Inverter
FR-A700
series
61924 (F1E4H) E4H — Parameter write error
61926 (F1E6H) E6H — Output stop
61927 (F1E7H) E7H — Emergency stop
61936 (F1F0H) F0H OL Stall prevention (overcurrent)
61937 (F1F1H) F1H oL Stall prevention (overvoltage)
61938 (F1F2H) F2H PS PU stop
61939 (F1F3H) F3H RB Regenerative brake pre-alarm
61940 (F1F4H) F4H TH Electronic thermal relay function
pre-alarm
61941 (F1F5H) F5H MT Maintenance signal output
61942 (F1F6H) F6H CP Parameter copy
61943 (F1F7H) F7H SL Speed limit indication (Output during
speed limit)
61944 (F1F8H) F8H Fn Fan alarm