5 - 103
Chapter 5 Data Used for Positioning Control
Item
Setting value
Default
value
Buffer memory address
Value set with GX Works2 Value set with sequence program
QD77MS2
QD77MS4
QD77MS16
[Da.11]
Shape
0 : End 0
b15 b0b3b7b11
000
Start data No.
Shape
0000
H 26000+1000n 22000+400n
1 : Continue 1
[Da.12]
Start data No.
Positioning data No.:
1 to 600
(01H to 258H)
01H
to
258H
[Da.13]
Special start
instruction
0 : Block start (normal start) 00H
b15 b11 b7 b0b3
Special start
instruction
Parameter
0000
H 26050+1000n 22050+400n
1 : Condition start 01H
2 : Wait start 02H
3 : Simultaneous start 03H
4 : FOR loop 04H
5 : FOR condition 05H
6 : NEXT start 06H
[Da.14]
Parameter
Condition data No.:
1 to 10 (01H to 0AH)
Number of repetitions:
0 to 255 (00H to FFH)
00H
to
FFH
n: Axis No.-1