5 - 173
Chapter 5 Data Used for Positioning Control
Setting value
Default
value
Buffer memory address
QD77MS2
QD77MS4
QD77MS16
Set with a decimal.
A
ctual value
Conversion into an integer value
Cd.16 Inching movement amount
10
m
Unit conversion table ( Cd.16 )
m
1
5
5
0
R
Setting value
(Decimal)
inch
degree
PLS
Unit
m
Example: When the " Cd. 16 Inching
movement amount" is set as
"1.0 m", the buffer memory
stores "10".
0 1517+100n 4317+100n
Set with a decimal.
Actual value
Conversion into an integer value
Cd.17 JOG speed
10
m
Unit conversion table ( Cd.17 )
mm/min
inch/min
degree/min
m
2
3
3
0PLS/s
Unit
R
Setting value
(Decimal)
Example: When the " Cd. 17 JOG
speed" is set as "20000.00mm
/min", the buffer memory
stores "2000000".
: When " Pr.83 Speed
control 10 x multiplier
setting for degree axis"
is valid: "2"
0
1518+100n
1519+100n
4318+100n
4319+100n
Set with a decimal.
Setting
value
Interruption request continuous operation
1: Interrupts continuous operation control
or continuous path control.
K
The Simple Motion module resets the value to "0" automatically when the
continuous control interruption request is processed.
(This indicates the completion of continuous operation interruption request.)
1
0 1520+100n 4320+100n
n: Axis No.-1