6 - 33
Chapter 6 Sequence Program Used for Positioning Control
DMOVP K50000
Position
ing addr
ess
* <Setting of positioning address >
D246
* <Positioning address >
DMOVP K18000000 D246
For Unit
(degree
)
X4D
Position
ing addr
ess
* <Command speed >
DMOVP K1800000 D244
For Unit
(degree
)
X4D
DMOVP K9000
Command
speed
* <Setting of command speed >
D244
Command
speed
* <Setting of dwell time >
MOVP K0
Dwell ti
me
D242
* < (Dummy data) >
MOVP K0
(Dummy)
D243
*
* No.2-9 Positioning data setting program
* (For positioning data No.15 <Axis 1>)
* <Positioning identifier>
*
Operation pattern: Positioning terminated
* Control system: 1-axis liner control (INC)
* Acceleration time No. : 0, deceleration time No. : 0
*
MOVP K0
M code
* <Setting of M code >
MOVP H200
* <Setting of positioning identifie >
D240
D241
SM402
ON for 1
scan onl
y after
RUN
562
Position
ing iden
tifier