5 - 176
Chapter 5 Data Used for Positioning Control
Setting item Setting details
[Cd.23] Speed-position switching
control movement amount
change register
During the speed control stage of the speed-position switching control (INC
mode), it is possible to change the specification of the movement amount during
the position control stage. For that, use this data item to specify a new movement
amount.
The new movement amount has to be set during the speed control stage of the
speed-position switching control (INC mode).
The value is reset to "0" when the next operation starts.
Set a value within the following range:
[Pr.1] Unit
setting
mm
(
10
-1
µm)
inch
(
10
-5
inch)
degree
(
10
-5
degree)
PLS
(PLS)
Setting range
0 to
2147483647
0 to
2147483647
0 to
2147483647
0 to
2147483647
Fetch cycle: At switching request
[Cd.24] Speed-position switching
enable flag
Set whether the switching signal set in "[Cd.45] Speed-position switching device
selection" is enabled or not.
Fetch cycle: At switching request
[Cd.25] Position-speed switching
control speed change register
During the position control stage of the position-speed switching control, it is
possible to change the specification of the speed during the speed control stage.
For that, use this data item to specify a new speed.
The new speed has to be set during the position control stage of the position-
speed switching control.
The value is reset to "0" when the next operation starts.
Set a value within the following range:
[Pr.1] Unit
setting
mm
(
10
-2
mm/min)
inch
(
10
-3
inch/min)
degree
(
10
-3
degree/min)
PLS
(PLS/s)
Setting range
0 to
2000000000
0 to
2000000000
0 to
2000000000
0 to 1000000000
: When "[Pr.83] Speed control 10 x multiplier setting for degree axis" is valid,
this will be the setting range 0 to 2000000000 (
10
-2
degree/min).
Fetch cycle: At switching request