Appendix - 79
Appendices
(7) External input signal
Set as the followings to fetch the external input signal (FLS/RLS/DOG) via
FR-A700 series.
• Set "1: External input signal of servo amplifier" in "[Pr.80] External input
signal selection".
• Set the parameters of the inverter as below.
(Otherwise, each signal remains OFF.)
Setting item
Default
value
Setting
value
Details
[Pr.178]
STF
terminal
function
selection
60 60
Use with the default value.
[Pr.179]
STR
terminal
function
selection
61 61
Use with the default value.
[Pr.185]
JOG
terminal
function
selection
5 76
Set 76 (Near-point dog).
[Pr.449]
SSCNET
input filter
setting
4
0: None
1: 0.88ms
2: 1.77ms
3: 2.66ms
4: 3.55ms
Set the input filter setting value at
reading an external signal.
• Set the servo parameter of Simple Motion module "Input filter setting
(PD11)" to be the same value as the parameter of the inverter "[Pr.449]
SSCNET
input filter setting".
Setting item
Default
value
Setting
value
Details
PD11
Input filter
setting
4
0: None
1: 0.88ms
2: 1.77ms
3: 2.66ms
4: 3.55ms
Set the input filter setting value at
reading an external signal.