48
8.1 System Setting Screen
The following is an explanation of the items found in the System Settings window.
Function group Function Operation details
User set-up Allow or disallow certain functions
Site name set-up Set the building name
[User Set-up group]
Password set-up The password can be changed
AG-150A/G-50A
connection set-up
Sets the number of AG-150A/G-50A units connected and the IP address.
System configuration
set-up
Sets the system configuration, group, interlocking unit, etc.
DIDO, AI, PI controller
set-up
Sets the each item of DIDO, AI, PI controller.
PLC for general equipment
set-up
Sets the number of PLC units, and general equipment functions and
names, etc.
Monitoring screen set-up Executes the model name setting, plane drawing creation, group icon
arrangement, etc.
Measurement meter set-up
(Watt hour meter set-up)
Sets the number of PLC units, and meter type, name and pulse unit, etc.
(Set the watt hour meter serial port and watt hour meter address)
Energy monitoring set-up Set the system billing function
Charge set-up Sets the basic charge, seasonal/interval, weekly charge, and annual
charges, etc.
Energy saving set-up Sets the control operation, etc., for energy saving operation.
Night mode set-up Sets the night mode target and time.
System-changeover set-up Sets the refrigerant target and changeover mode, etc., for
automatically changing between cooling and heating.
IC I/O signal set-up Sets the general equipment connected to the IC I/O signal, etc.
[System Set-up
group]
Time set-up Set the current time. Each AG-150A/G-50A time can be monitored.
Maintenance of charge
data
Proportional billing information can be revised.
The WHM present value can be monitored or changed (overwritten).
Operation amount/electric
amount data monitor
The AG-150A/G-50A operation amount, PLC measurement/power amount
data can be monitored and overwritten.
Remedial apportioning
setting
Remedial apportioning can be tentatively performed when charging trouble
occurs.
Maintenance of comparison
data for energy monitoring
The data used to compare apportioned parameters when the
AG-150A/G-50A or PLC fails can be cleared.
[Maintenance group]
Test run for energy
monitoring
Operation can be tried to confirm that the charge function is operating
correctly.
Note:
• Refer to Chapter 9 for the maintenance group items.
• The set items that are displayed depend on the functions of theTG-2000A purchased.
8. System Setting Procedu
r
e
Initial windo
w
User Se
t
u
p
grou
p
Maintenance grou
p
System Se
t
-
u
p
grou
p