130
[Without WHM connection]
Proportional division parameter for the outdoor unit:
The proportional division parameter calculated with the power used by the indoor unit concerned,
as that used by the outdoor unit (cryogenic) using the proportionally divided reference data, indoor
unit capacity, and other data selected.
Proportional division parameter for indoor unit:
The proportional division parameter calculated with the power used by the indoor unit concerned,
as that used by the indoor unit itself (power and auxiliary heating) using the fan operation time,
power input, and other parts of the indoor unit, etc.
[With WHM connection]
Apportioned electric power for outdoor unit:
The electric power proportionally divided from the electric power used by WHM with the power
used by the indoor unit concerned, as that used by the outdoor unit (cryogenic) using the
proportionally divided reference data, indoor unit capacity, and other data.
Apportioned electric power for indoor unit:
The electric power proportionally divided from the electric power used by WHM with the power
used by the indoor unit concerned, as that used by the indoor unit itself (power and subsidiary
heating) using the fan operation time, power input, and other parts of the indoor unit, etc.
9.2.3 Unit Data Maintenance
The proportional division data for every indoor unit may be changed. This screen displays the capacity
save ratio, thermo-ON time, the FAN operating time or subsidiary heater operation time for regular hours
and off hours.
Maintaining Apportioned Unit Data
[Procedure]
1) Select the selection method.
Click the [Select from AG-150A/G-50A] or [Select
from charging block] check box in the upper left part
of the charge data maintenance screen.
2-1) Select the selection method from AG-150A/G-50A.
Select the [Select from AG-150A/G-50A] button in
accordance with the procedure shown in 1), and click
the
mark in the [AG-150A/G-50A No.] selection
box to select the AG-150A/G-50A No. to be
displayed. When it is selected, the indoor unit
connected to the AG-150AG-50A is displayed in the
unit selection column.
2-2) Select the selection method from the charging block.
Select the [Select from charge block] button in
accordance with the procedure shown in 1), and click
the
mark in the [Select of charge block] selection
box to select the charge block to be displayed. When
it is selected, the group set to the charge block is
displayed in the unit selection column.
Click the group, which sets the indoor unit to be
displayed. When it is selected, the indoor unit set to
the group is displayed in the unit selection column.
2-3) Select the selection method from WHM.
Select the [Select from WHM] button in accordance
with the procedure shown in 1), and click the
mark in the WHM box. When it is selected, the unit
set to WHM is displayed in the unit selection column.
If the outdoor unit is clicked when the outdoor unit is
displayed, the indoor unit composing of the outdoor
unit is displayed in the unit selection column.
Select button
AG-150A/G-50A No.
select box
Charge data maintenance screen
(select from AG-150A/G-50A)
Char
g
e data maintenance screen
(
select from char
g
e block
)
Char
g
e block select
Group select