APPENDIX
App. - 50
App. 12.2 Magnetic contactor
Use a magnetic contactor with an operation delay time (interval between current being applied to the coil
until closure of contacts) of 80 ms or less.
Servo amplifier
Magnetic
contactor
Servo amplifier
Magnetic
contactor
MR-J4-10B(-RJ) MR-J4-60B4(-RJ)
MR-J4-20B(-RJ) MR-J4-100B4(-RJ) SD-N11
MR-J4-40B(-RJ)
SD-N11
MR-J4-200B4(-RJ)
MR-J4-60B(-RJ) MR-J4-350B4(-RJ)
MR-J4-70B(-RJ) MR-J4-500B4(-RJ) SD-N21
MR-J4-100B(-RJ) MR-J4-700B4(-RJ)
MR-J4-200B(-RJ)
SD-N21
MR-J4-11KB4(-RJ) SD-N25
MR-J4-350B(-RJ) MR-J4-15KB4(-RJ) SD-N35
MR-J4-500B(-RJ) SD-N35 MR-J4-22KB4(-RJ) SD-N50
MR-J4-700B(-RJ)
SD-N50
MR-J4-10B1(-RJ)
MR-J4-11KB(-RJ) MR-J4-20B1(-RJ) SD-N11
MR-J4-15KB(-RJ) SD-N65 MR-J4-40B1(-RJ)
MR-J4-22KB(-RJ) SD-N95