11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 79
Servo amplifier
Power factor
improving AC
reactor
Dimensions
Dimensions [mm]
Terminal
size
Mass
[kg]
W W1 H D (Note) D1 D2 d
MR-J4-10B(-RJ)
MR-J4-20B(-RJ)
MR-J4-10B1(-RJ)
FR-HAL-0.4K
Fig. 11.7
104 84 99 72 51 40 M5 M4 0.6
MR-J4-40B(-RJ)
MR-J4-20B1(-RJ)
FR-HAL-0.75K 104 84 99 74 56 44 M5 M4 0.8
MR-J4-60B(-RJ)
MR-J4-70B(-RJ)
MR-J4-40B1(-RJ)
FR-HAL-1.5K 104 84 99 77 61 50 M5 M4 1.1
MR-J4-100B(-RJ) FR-HAL-2.2K
115
(Note)
40 115 77 71 57 M6 M4 1.5
MR-J4-200B(-RJ) FR-HAL-3.7K
115
(Note)
40 115 83 81 67 M6 M4 2.2
MR-J4-350B(-RJ) FR-HAL-7.5K
Fig. 11.8
130 50 135 100 98 86 M6 M5 4.2
MR-J4-500B(-RJ) FR-HAL-11K 160 75 164 111 109 92 M6 M6 5.2
MR-J4-700B(-RJ) FR-HAL-15K 160 75 167 126 124 107 M6 M6 7.0
MR-J4-11KB(-RJ) FR-HAL-15K 160 75 167 126 124 107 M6 M6 7.0
MR-J4-15KB(-RJ) FR-HAL-22K
185
(Note)
75 150 158 100 87 M6 M8 9.0
MR-J4-22KB(-RJ) FR-HAL-30K Fig. 11.9
185
(Note)
75 150 168 100 87 M6 M10 9.7
Note. Maximum dimensions The dimension varies depending on the input/output lines.
(2) 400 V class
W ± 0.5
W1
RX ZSYT
H ± 5
D1
D2
4-d mounting hole (Note)
(φ5 groove)
D or less
Fig. 11.10
Y
Z
S
T
MCMCCB
FR-HAL-H
Servo amplifie
r
3-phase
400 V class
XR
L1
L2
L3
3-phase
380 V AC to
480 V AC