8. TROUBLESHOOTING
8 - 6
No. Name
Detail
number
Detail name
Stop
method
(Note 4,
5)
Alarm deactivation
Alarm
reset
CPU
reset
Cycling
the
power
Alarm
71
Load-side encoder normal
communication error 1
71.1
Load-side encoder communication - Receive
data error 1
EDB
71.2
Load-side encoder communication - Receive
data error 2
EDB
71.3
Load-side encoder communication - Receive
data error 3
EDB
71.5
Load-side encoder communication -
Transmission data error 1
EDB
71.6
Load-side encoder communication -
Transmission data error 2
EDB
71.7
Load-side encoder communication -
Transmission data error 3
EDB
71.9
Load-side encoder communication -
Transmission data error 4
EDB
71.A
Load-side encoder communication -
Transmission data error 5
EDB
72
Load-side encoder normal
communication error 2
72.1 Load-side encoder data error 1 EDB
72.2 Load-side encoder data update error EDB
72.3 Load-side encoder data waveform error EDB
72.4 Load-side encoder non-signal error EDB
72.5 Load-side encoder hardware error 1 EDB
72.6 Load-side encoder hardware error 2 EDB
72.9 Load-side encoder data error 2 EDB
82
Master-slave operation
error 1
82.1 Master-slave operation error 1 EDB
8A
USB communication time-
out error
8A.1 USB communication time-out error SD
8E USB communication error
8E.1 USB communication receive error SD
8E.2 USB communication checksum error SD
8E.3 USB communication character error SD
8E.4 USB communication command error SD
8E.5 USB communication data number error SD
888 Watchdog 88._ Watchdog DB
Note 1. Leave for about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. The alarm can be canceled by setting as follows:
For the fully closed loop control: set [Pr. PE03] to "1 _ _ _".
When a linear servo motor or a direct drive motor is used: set [Pr. PL04] to "1 _ _ _".
4. The following shows three stop methods of DB, EDB, and SD.
DB: Stops with dynamic brake. (Coasts for the servo amplifier without dynamic brake.)
EDB: Electronic dynamic brake stop (available with specified servo motors)
Refer to the following table for the specified servo motors. The stop method for other than the specified
servo motors will be DB.
Series Servo motor
HG-KR HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR HG-SR51/HG-SR52
SD: Forced stop deceleration
5. This is applicable when [Pr. PA04] is set to the initial value. The stop system of SD can be changed to DB using
[Pr. PA04].
6. This alarm will occur only in the J3 compatibility mode.