10. CHARACTERISTICS
10 - 14
(3) 100 V class
The following shows the inrush currents (reference data) that will flow when 120 V AC is applied at the
power supply capacity of 2500 kVA and the wiring length of 1 m.
Servo amplifier
Inrush currents (A
0-P
)
Main circuit power supply
(L1 and L2)
Control circuit power supply
(L11 and L21)
MR-J4-10B1(-RJ)
MR-J4-20B1(-RJ)
MR-J4-40B1(-RJ)
38 A
(attenuated to approx. 14 A in 10 ms)
20 A to 30 A
(attenuated to approx. 0 A
in 1 ms to 2 ms)