5. PARAMETERS
5 - 12
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA02 **REG Regenerative option
Used to select the regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 37 Parameter
error] occurs.
Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ x x Regenerative option selection
00: Regenerative option is not used.
For servo amplifier of 100 W, regenerative resistor is not
used.
For servo amplifier of 0.2 kW to 7 kW, built-in regenerative
resistor is used.
Supplied regenerative resistors or regenerative option is used
with the servo amplifier of 11 kW to 22 kW.
01: FR-RC-(H)/FR-CV-(H)/FR-BU2-(H)
When you use FR-RC-(H) or FR-CV-(H), "Mode 2 (_ _ _ 1)" of
"Undervoltage alarm detection mode selection" in [Pr. PC20].
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50 (Cooling fan is required.)
08: MR-RB31
09: MR-RB51 (Cooling fan is required.)
0B: MR-RB3N
0C: MR-RB5N (Cooling fan is required.)
80: MR-RB1H-4
81: MR-RB3M-4 (Cooling fan is required.)
82: MR-RB3G-4 (Cooling fan is required.)
83: MR-RB5G-4 (Cooling fan is required.)
84: MR-RB34-4 (Cooling fan is required.)
85: MR-RB54-4 (Cooling fan is required.)
91: MR-RB3U-4 (Cooling fan is required.)
92: MR-RB5U-4 (Cooling fan is required.)
FA: When the supplied regenerative resistors or the regenerative
option is cooled by the cooling fan to increase the ability with
the servo amplifier of 11 kW to 22 kW.
00h
_ x _ _ For manufacturer setting 0h
x _ _ _ 0h