(4) Selection example of wires used for wiring
POINT
Selection conditions of wire size is as follows.
600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
(a) Wire size
1) Between P and P4, and between N and N-
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV and servo amplifier.
Total of servo amplifier capacities [kW] Wire [mm
2
]
1 or less 2 (AWG 14)
2 3.5 (AWG 12)
5 5.5 (AWG 10)
7 8 (AWG 8)
11 14 (AWG 6)
15 22 (AWG 4)
22 50 (AWG 2)
The following table indicates the connection wire sizes of the DC power supply (P4, N- terminals)
between the FR-CV-H and servo amplifier.
Total of servo amplifier capacities [kW] Wire [mm
2
]
11 8 (AWG 8)
15 8 (AWG 8)
22 14 (AWG 6)
(2) Grounding
For grounding, use the wire of the size equal to or greater than that indicated in the following
table, and make it as short as possible.
Power regeneration common
converter
Grounding wire size
[mm
2
]
FR-CV-7.5K to FR-CV-15K 8 (AWG 8)
FR-CV-22K/FR-CV-30K 22 (AWG 4)
FR-CV-37K/FR-CV-55K 38 (AWG 2)
FR-CV-H22K/FR-CV-H30K 8 (AWG 8)
FR-CV-H37K/FR-CV-H55K 14 (AWG 6)