11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 101
11.18 Heat sink outside mounting attachment (MR-J4ACN15K/MR-J3ACN)
Use the heat sink outside mounting attachment to mount the heat generation area of the servo amplifier in
the outside of the cabinet to dissipate servo amplifier-generated heat to the outside of the cabinet and
reduce the amount of heat generated in the cabinet. In addition, designing a compact cabinet is allowed.
In the cabinet, machine a hole having the panel cut dimensions, fit the heat sink outside mounting
attachment to the servo amplifier with the fitting screws (4 screws supplied), and install the servo amplifier to
the cabinet.
Please prepare screws for mounting. They do not come with.
The environment outside the cabinet when using the heat sink outside mounting attachment should be within
the range of the servo amplifier operating environment.
The heat sink outside mounting attachments are used for MR-J4-11KB(-RJ) to MR-J4-22KB(-RJ) and MR-
J4-11KB4(-RJ) to MR-J4-22KB4(-RJ).
The following shows the combinations.
Servo amplifier
Heat sink outside mounting
attachment
MR-J4-11KB(-RJ)
MR-J4-15KB(-RJ)
MR-J4ACN15K
MR-J4-22KB(-RJ) MR-J3ACN
MR-J4-11KB4(-RJ)
MR-J4-15KB4(-RJ)
MR-J4ACN15K
MR-J4-22KB4(-RJ) MR-J3ACN
(1) MR-J4ACN15K
(a) Panel cut dimensions
[Unit: mm]
196
218
18
510
410
535
Approx.
125
163
4-M10 Screw
Punched
hole
(b) How to assemble the attachment for heat sink outside mounting attachment
Screw
(2 places)
Attachment