Mitsubishi Electronics MR-J4-_B_(-RJ) Air Conditioner User Manual


 
5. PARAMETERS
5 - 21
No. Symbol Name and function
Initial
value
[unit]
Setting
range
PA25 OTHOV One-touch tuning - Overshoot permissible level
This is used to set a permissible value of overshoot amount with a percentage to in-position
range.
However, setting "0" will be 50%.
0
[%]
0 to 100
PA26 *AOP5 Function selection A-5 Refer to the
"Name and
function" column.
Setting
digit
Explanation
Initial
value
_ _ _ x Torque limit function selection at instantaneous power failure
(instantaneous power failure tough drive selection)
0: Disabled
1: Enabled
When an instantaneous power failure occurs during operation, you
can save electric energy charged in the capacitor in the servo
amplifier by limiting torque at acceleration. You can also delay the
time until [AL. 10.2 Voltage drop in the main circuit power] occurs
with instantaneous power failure tough drive function. Doing this will
enable you to set a longer time in [Pr. PF25 SEMI-F47 function -
Instantaneous power failure detection time].
To enable the torque limit function at instantaneous power failure,
select "Enabled (_ 1 _ _)" of "SEMI-F47 function selection" in [Pr.
PA20].
This parameter setting is used with servo amplifier with software
version A6 or later.
0h
_ _ x _ For manufacturer setting 0h
_ x _ _ 0h
x _ _ _ 0h