Mitsubishi Electronics MR-J4-_B_(-RJ) Air Conditioner User Manual


 
1. FUNCTIONS AND CONFIGURATION
1 - 23
1.6 Model designation
(1) Rating plate
The following shows an example of rating plate for explanation of each item.
Country of origin
Model
Capacity
Applicable power supply
Rated output current
Standard, Manual number
Ambient temperature
IP rating
KC certification number, The year and month of manufacture
Serial number
TOKYO 100-8310, JAPAN MADE IN JAPAN
IP20
KCC-REI-MEK-TC300A624G51
Max. Surrounding Air Temp.: 55°C
POWER :100W
MR-J4-10B
AC SERVO
SER.A45001001
OUTPUT: 3PH170V 0-360Hz 1.1A
MAN.: IB(NA)0300175
INPUT : 3AC/AC200-240V 0.9A/1.5A 50/60Hz
STD.: IEC/EN 61800-5-1
DATE:2014-05
MODEL
(2) Model
The following describes what each block of a model name indicates. Not all combinations of the symbols
are available.
Series
Rated output
SSCNETIII/H interface
Special specifications
Symbol Rated output [kW]
10 0.1
20 0.2
40 0.4
Symbol Special specifications
None Standard
MR-J4-_B_ without regenerative resistor (Note 1)
MR-J4-_B_-RJ without regenerative resistor (Note 1)
-RJ
Fully closed loop control four-wire type/
load-side encoder A/B/Z-phase input compatible/
Compatible with MR-D30 functional safety unit
60 0.6
70 0.75
100 1
200 2
350 3.5
500 5
700 7
11K 11
15K 15
22K 22
-PX
-RZ
Indicates a servo amplifier of 11 kW to 22 kW that
does not use a regenerative resistor as standard
accessory. Refer to Appendix 11.2 for details.
Note1.
Power supply
Symbol Power supply
None
3-phase or 1-phase
200 V AC to 240 V AC
4
3-phase 380 V AC to 480 V AC
1
1-phase 100 V AC to 120 V AC
Dynamic brake which is built in 7 kw or smaller servo
amplifiers is removed. Refer to Appendix 11.1 for details.
2.
MR-J4-_B_ without a dynamic brake (Note 2)
MR-J4-_B_-RJ without a dynamic brake (Note 2)
-ED
-RU