Mitsubishi Electronics MR-J4-_B_(-RJ) Air Conditioner User Manual


 
10. CHARACTERISTICS
10 - 6
Servo amplifier Servo motor
(Note 1)
Power supply
capacity
[kVA]
(Note 2) Servo amplifier-generated heat [W]
Area required for
heat dissipation
[m
2
]
At rated output
At rated output
[Generated heat
in the cabinet
when cooled
outside the
cabinet] (Note 3)
With servo-off
MR-J4-11KB(-RJ)
HG-JR903 13 435 130 45 8.7
HG-JR11K1M 16 530 160 45 11.0
HG-JR801 12 370 110 45 7.0
HG-JR12K1 18 570 170 45 11.5
MR-J4-15KB(-RJ)
HG-JR15K1M 22 640 195 45 13.0
HG-JR15K1 22 640 195 45 12.8
MR-J4-22KB(-RJ)
HG-JR22K1M 33 850 260 55 17.0
HG-JR20K1 30 800 240 55 16.0
HG-JR25K1 38 900 270 55 19.0
MR-J4-60B4(-RJ)
HG-SR524 1.0 40
18 0.8
HG-JR534 1.0 40 18 0.8
HG-SR1024 1.7 60 18 1.2
MR-J4-100B4(-RJ) HG-JR734 1.3 60 18 1.2
HG-JR1034 1.7 60 18 1.2
HG-SR1524 2.5 90 20 1.8
MR-J4-200B4(-RJ)
HG-SR2024 3.5 90 20 1.8
HG-JR1534 2.5 90 20 1.8
HG-JR2034 3.5 90 20 1.8
MR-J4-350B4(-RJ)
HG-SR3524 5.5 130 20 2.6
HG-JR3534 5.5 160 20 2.7
MR-J4-500B4(-RJ)
HG-SR5024 7.5 195 25 3.9
HG-JR5034 7.5 195 25 3.9
MR-J4-700B4(-RJ)
HG-SR7024 10 300 25 6.0
HG-JR7034 10 300 25 6.0
HG-JR701M4 10 300 25 6.0
HG-JR6014 8.6 250 25 5.0
MR-J4-11KB4(-RJ)
HG-JR9034 13 435 130 45 8.7
HG-JR11K1M4 16 530 160 45 11.0
HG-JR8014 12 370 110 45 7.0
HG-JR12K14 18 570 170 45 11.5
MR-J4-15KB4(-RJ)
HG-JR15K1M4 22 640 195 45 13.0
HG-JR15K14 22 640 195 45 12.8
MR-J4-22KB4(-RJ)
HG-JR22K1M4 33 850 260 55 17.0
HG-JR20K14 30 800 240 55 16.0
HG-JR25K14 38 900 270 55 19.0
MR-J4-10B1(-RJ)
HG-MR053 0.3 25
15 0.5
HG-MR13 0.3 25 15 0.5
HG-KR053 0.3 25 15 0.5
HG-KR13 0.3 25 15 0.5
MR-J4-20B1(-RJ)
HG-MR23 0.5 25 15 0.5
HG-KR23 0.5 25 15 0.5
MR-J4-40B1(-RJ)
HG-MR43 0.9 35 15 0.7
HG-KR43 0.9 35 15 0.7
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value is applicable when the
power factor improving AC reactor or power factor improving DC reactor are not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 11.2.
3. This value is applicable when the servo amplifier is cooled by using the heat sink outside mounting attachment.