Bosch Appliances 3.5 Home Security System User Manual


 
Bosch Security Systems | 2011-02
Praesideo 3.5 | Installation and User Instructions | 3 | Control Equipment en | 98
table 5.11: Faults event table
Fault Detail Logging message
A/B fault (channel) Group A or B line fault
Amp missing (channel) Amplifier missing
Amp standby Amplifier initialization failure
Audio path Call station audio path fault
CobraNet fault code CobraNet network fault: fault code
Config file Not valid
Mismatch
Error
No valid configuration file found; a new configuration file
will be created
Configuration file version mismatch: version x.xx found
y.yy expected
Configuration file error
Ctrl input (control input) Control input line failure
End of line (channel) Loudspeaker line failure
Failure (channel)
(channel)
Amplifier failure
Amplifier failure or overload
Fault input (text) Fault input
Flashcard Missing
Checksum
Message names
Flash card missing
Flash card data error
Messages missing:
Gnd short (channel) Amplifier ground short
Grp A fault (channel) Group A fault
Grp B fault (channel) Group B fault
HW Version Mismatch Hardware version mismatch
Internal Fault (number) Cobranet interface fault
Keypad n/m mismatch Keypad mismatch
Line input (audio input) Line input failure
Loop fault (channel) Class-A switchover
Loudspeaker (channel) Loudspeaker failure
Lsp Line (channel) Amplifier loudspeaker line failure
Memory EEPROM
FLASH
Memory error
Mic input (audio input) Microphone Failure
Missing Unit missing
Net pwr RCS Network power supply failure remote call station
No mains Mains power supply failure
No sec pwr Back up power supply failure
Overheat (channel) Amplifier overheat
Overload (channel)
(channel)
Amplifier overload
Amplifier short circuit
Proc reset MMP
CPU
CNM
SCB
Processor reset: MMP (network processor)
Processor reset: CPU (system processor)
Processor reset: CNM (CobraNet module)
Processor reset: SCB (supervision control board)
RCS connect Remote call station connection failure
Ring broken System Network Redundant ring broken
SCB failure Supervision Control Board failure