Event message:
Group B fault
Originator:
Output channel of multi channel interface, connected
to a basic amplifier channel in which the fault
occurred.
Extra information:
----
Description:
Logs the failure in group B for audio outputs with A/B
switching or class-A wiring.
Resolve:
When the unit disconnects or when the fault is
resolved manually.
Recommended action:
Check the loudspeaker connections on the Group B
output of the basic amplifier channel.
Event message:
Incompatible hardware version
Originator:
Unit in which the fault occurred.
Extra information:
The version number of the installed hardware and the
lowest version number that is required to use the
configured functionality.
Description:
Logs the mismatch of the version number of the unit
hardware and the required hardware version number.
The mismatch depends on the configured functionality
of the unit. This fault event only occurs when the
configured functionality cannot be handled by the
hardware. Typically, this event occurs when multiple
loudspeaker line supervision is used in combination
with /00 Power Amplifiers.
Resolve:
When the unit disconnects.
Recommended action:
Use a newer version of the unit that caused the
fault OR
Downgrade to a lower software version
Event message:
Invalid Firmware version
Originator:
Unit that has an invalid firmware version.
Extra information:
Current firmware version number of the unit and the
minimal required version number of the firmware.
Description:
Logs the mismatch of the firmware version number of
the unit and the minimal required firmware version
number.
Resolve:
When the unit is upgraded.
Recommended action:
Update firmware. This action is available in the
configuration web pages.
Event message:
Keypad mismatch
Originator:
Call station in which the fault occurred.
Extra information:
KP: keypad, NKP: numeric keypad.
Description:
Logs the mismatch of the number of configured and
detected (numeric) keypads.
Resolve:
When the fault disappears or when the call station
disconnects.
Recommended action:
Make sure that the number of configured (numeric)
keypads is equal to the number of (numeric) keypads