Praesideo 3.5 | Installation and User Instructions | 11 | Optional Software en | 450
56.7.2 Connections
56.7.2.1 Introduction
The Logging Server can log the events generated by up to
64 systems. The connections to the systems must be
defined on the Connections tab.
56.7.2.2 Add a system
Proceed as follows:
1 Click in the Enabled field of the row that is marked
with an asterisk (*). A new row is added to the list of
systems (see figure 56.6).
2 Click the System Name field and enter the name of the
system to which the Logging Server must connect. The
name may consist of up to 16 characters. For
example, System 4 (see figure 56.7).
3 Click the System Name or IP Address field and enter the
IP address or the name of the network controller of
the system to which the Logging Server must connect.
For example, 192.168.0.18 (see figure 56.8).
56.7.2.3 Disable event logging for a system
To disable the event logging for a system, remove the
check mark from its Enabled check box.
figure 56.6: Add a system (1)
figure 56.7: Add a system (2)
Note
If the name of the network controller is used, the
IP address of the network controller must be
stored in the Windows hosts file
(WINNT\system32\drivers\etc.). This file can be
edited with Notepad.
figure 56.8: Add a system (3)