18.3 Installation
The call station kit contains six holes for installation
purposes (see figure 18.12).
The kit is delivered together with Tyco AMP pin
headers and Tyco AMP 1-141708-1 shrink-contacts (see
figure 18.13) to facilitate the connection of wires to the
PCB. These pin headers are suitable for wires with a
cross-section from 0.2 to 0.56 mm
2
. It is possible to
solder the wires to the pin headers.
To connect the wires to the shrink-contacts, use one of
the following pliers:
Tyco AMP 169111-1 pliers (see figure 18.14)
Tyco AMP Modu 4 169481-1 pliers (see figure 18.15)
figure 18.12: Installation
Note
If the call station kit is installed in a vibrating
surrounding (e.g. a ship), glue the pin header to
the PCB.
figure 18.13: Tyco AMP 1-141708-1 shrink-contact
3,2 +/- 0.1
118 +/- 0.2
(6x)
108
5
130 +/- 0.2
60
60
5
figure 18 .14: Tyco AM P 16 9111-1 pliers
figure 18.15: Tyco AMP Modu 4 169481-1 pliers
1
3
5
5
mm
2
4
2.5
1.5
1
0.5-0.75
2
4
6
169111- 1
169481-1
MODU 4
0.
0
3
0.2
0
.1
2
0.
09
0.56
0
.1
4