Event message:
Redundant supply 24V
Originator:
Amplifier channel in which the fault occurred.
Extra information:
----
Description:
Logs the occurrence of a redundant power fault. If this
fault occurs, a redundant 24V internal power supply of
a basic amplifier (BAM) has failed. The BAM is
capable of functioning with the remaining 24V internal
power supply. Note that all BAM channels will report
this fault. This fault is masked by an active Amplifier
Overheat Mute fault, but both may be present if the
occurrence is: Redundant Supply 24V followed by an
Amplifier Overheat Mute fault.
Resolve:
When the fault is restored. If this fault is
acknowledged/reset, any Amplifier Overheat Mute
fault in the same amplifier channel will also be
acknowledged/reset.
Recommended action:
Check the CAT-5 connections between the multi
channel interface and indicated basic amplifier
channel.
Event message:
Remote call station connection failure
Originator:
Call station interface that detects the connection
failure with the remote call station.
Extra information:
----
Description:
Logs a connection failure between a call station
interface and a remote call station.
Resolve:
When the call station interface disconnects or when
the fault is no longer present.
Recommended action:
Check the connection between the call station
interface and the remote call station.
Make sure that all PRS-CSR(K) remote call
stations are connected to PRS-CSI Call Station
Interfaces.
Make sure that all LBB4438/00 and LBB4439/00
remote call stations are connected to
LBB4437/00 Call Station Interfaces.