Praesideo 3.5 | Installation and User Instructions | 11 | Optional Software en | 464
interconnections and give them a unique name for
reference purposes.
These interconnections are only used for normal calls
and emergency calls, not for BGM.
Outputs (zones) that are used for interconnections
cannot be selected anymore as zone outputs for layout
configuration, see section 59.5.4.7.
Inputs that are used for interconnections cannot be
selected anymore as audio input for live speech,
see section 59.5.4.4.
59.5.4.4 Configure PC Call Station Zone Groups...
This item configures the special PC Call Station zone
groups.
PC Call Station zone groups exist only on the PC Call
Station, not on the connected NCOs. Normal zones or
zone goups that have been defined on an NCO can be
added to such a group. This allows a PC Call Station
zone group to contain zone groups from different
NCOs, even a multi-NCO All Call zone group is
possible. PC Call Station zone groups can be configured
for predefined calls, just like normal zones and NCO
zone groups.
59.5.4.5 Configure Predefined Calls…
This item configures the predefined calls that can be
made from the PC Call Station Clients.
Use the Add new, Delete and Copy to new icons to create
new predefined calls and give them a unique name for
reference purposes. This name will appear on the screen
button of the PC Call Station Client for selecting this
predefined call. It is also shown here in a copy of a
PC Call Station Client button to check whether the name
fits.
The checkbox Use for PC TI defines whether this
predefined call can also be used by the PC Telephone
Interface Client. If this checkbox is checked, then a
Numerical alias must be entered for this predefined call.
This field only accepts numbers and the number must
be unique. This way users can call in to Praesideo, using
a telephone, and select a predefined call with the
numeric keypad of the telephone. See section 61.6.
Predefined calls are similar to call macros in Praesideo.
Each call must have a priority and can have a start tone,
end tone, messages that can be repeated, and a live
speech phase. The available tones and messages depend
on what information was retrieved from the network
controllers. It is important that all network controllers in
the system have the same tone set and message set,
because only tones and messages will be available for
selections that exist on all configured and connected
network controllers. In case of live speech an audio
input must be selected on a unit in one of the systems,
Note
Calls without live speech across multiple
subsystems use tones generated in each
subsystem individually and/or messages stored
in each subsystem. These tones and/or
messages are also logged as such. If these calls
include live speech, then only tones and/or
messages from the originating subsystem are
used and passed to all other subsystems, as
being live speech. This way, synchronization is
preserved but tones and messages broadcast
via the subsystems are not logged separately.
figure 59.9: Configure PC Call Station zone groups
figure 59.10: Configure predefined calls