25.6 Technical data
25.6.1 Physical characteristics
25.6.2 Climate conditions
25.6.3 EMC and Safety
25.6.4 Mean time between failure
25.6.5 System bus
25.6.6 External power supply
Dimensions (H x W x D):
27 x 243 x 80 mm (without bracket)
34 x 243 x 84 mm (with bracket)
Weight:
0.7 kg
Temp era tur e:
-5 to 55 °C (operating, guaranteed)
-15 to 55 °C (operating, sample tested)
-20 to 70 °C (non-operating)
Relative humidity:
15 to 90%, non-condensing (operating)
5 to 95%, non-condensing (non-operating)
Air pressure:
600 to 1100 hPa
Electromagnetic compatibility:
E N55103-1/ FCC -47 part 15B
E N55103-2
EN50121-4
EN50130-4
Electrical safety:
IEC60065 (CB-scheme)
EN60065
Approvals:
CE marking
EN60849, EN54-16 and ISO7240-16
IEC60945
MTBF:
50,000 hours at +55 °C
(The MTBF doubles for every 10 °C decrease in
temperature.)
Number of connections:
4x proprietary female connectors
Position:
Front and rear sides
Preferred cable:
LB B4416/xx
Maximum cable length:
50 m (per system bus connector)
Data signal interface:
Plastic optical fiber
Power supply via network:
18 to 56 V(D C)
No fault reporting when >20V
Network power consumption:
3.9 W
Connector:
Kycon KPP4-P
Input voltage:
48 V(DC)
Input voltage range:
18 to 56V (D C)
No fault reporting when >20V
Current:
5 A (peak, < 2 s)
2.5 A continuous