Bosch Appliances 3.5 Home Security System User Manual


 
Bosch Security Systems | 2011-02
Praesideo 3.5 | Installation and User Instructions | 6 | Installation Accessories en | 277
27.3 Wiring
See figure 27.4 for details about the wires inside the
extension cables.
27.4 Custom-made cables
Use LBB4418/00 Cable-connector Tool Kit to create
custom-made cables out of LBB4416/00 Network
Cables and LBB4417/00 Network Connectors.
27.5 Technical data
figure 27.4: Cable details
table 27.2: Cable details
Number Signal
1 Protective cloth
2 Insulation
3 Outer sheet
4 Stranded wire
5 Optical fiber
7±0.1
3
2
1
5
4
Insulation:
LSZH (low smoke/zero halogen), black
Outer diameter:
7 mm
Power supply wires (2):
Copper, stranded 1 mm
2
, red and brown insulation,
resistance < 0.018 ohm/m
Optical fibers (2):
PMMA, 1 mm diameter including cladding 2 mm
diameter (black)
Numeric aperture: 0.5
optical attenuation < 0.17 dB/m @ 650 nm
bending loss < 0.5 dB (r = 20 mm, 90°), according
to JIS C6861
Temperature range:
-40 to +65 °C
Pull force:
max. 150 N
UL-compliancy:
UL444 (60 °C/60 V),
Flame retardant:
according to IEC 60332-1 / 60 s
Halogen level:
according to IEC 60754-2, pH > 4.3 and
conductivity < 10 uS/mm
Smoke level:
according to IEC 61034-2, light transmittance > 60%