Emerson Process Management HASX2E-IM-HS Carbon Monoxide Alarm User Manual


 
Emerson Process Management GmbH & Co. OHG3-4
X-STREAM X2
Instruction Manual
HASX2E-IM-HS
02/2012
3.1 Infrared (IR) and Ultraviolet (UV) Measurement
Fig. 3-3: Photometer assembly principle
3.1.3 Technical Implementation
1 UV source
2 Adaptor cell
3 Analysis cell (internal view)
4 Filter cell
5 UV detector
6 Gas detector
7 IR detector electronics
8 Pyro detector (alternatively)
9 Temperature sensor
10 Filter for pyro detector assembly
11 Chopper
12 Chopper electronics
13 IR source
14 EDL
The radiation emitted by an IR or UV/EDL
source passes an adaptor cell, widening the
beam to completely ll out the analysis cell´s
diameter. At the opposite side of the cell,
another adaptor cell is installed to reduce
the beam to the diameter of the opening in
the chopper.
The detectors are installed at the rear side
of the chopper.
As pyrodetectors are not as
frequency selective as gas detectors, an ad-
ditional lter has to be installed when using
pyrodetectors, limiting the bandwidth of radi-
ation passing the chopper.
1
2
3
4
5
6
7
8
9
11 10
13
14
12