Emerson Process Management HASX2E-IM-HS Carbon Monoxide Alarm User Manual


 
Emerson Process Management GmbH & Co. OHG 2-17
X-STREAM X2
Instruction Manual
HASX2E-IM-HS
02/2012
2
Technical data
Power supply
Nominal input voltage 100–240 V 50/60 Hz,
wide range power supply unit
Input voltage range 85–264 V , 47–63 Hz
Nominal input current
XLF standard 1.3–0.7 A max.
with temperature control 3–1.5 A max.
XXF standard 1.5–0.8 A max.
with temperature control 5.5–3 A max.
Connection via touch proof screw-type
terminals internally mounted near the
cable glands (Fig. 2-9).
Wire cross-section: max. 4 mm
2
, end sleeves not required.
Cable entry via one IP 68 cable gland
Permissible cable outer diameter: 7–12 mm
Power supply fuses
Fuse holders are integrated within
power supply terminals
Data for fuse links: AC 230 V / T 6.3 A / 5x20 mm
2.2.3 Model-Specic Technical Data: X-STREAM X2XF Field Housings
Housing
Permissible operational ambient temperature: -20 °C to +50 °C (-4 °F to 122 °F)
Permissible ambient storage temperature: -20 °C to +70 °C (-4 °F to 158 °F)
Weight: XLF max. approx. 25 kg (57.2 lb)
XXF max. approx. 45 kg / 99.2 lb
Protection class: IP 66 (EN 60529) / NEMA 4X
for outdoor use
to be protected against direct sunlight
Gas connections: quantity: max. 8
optional
1 additional purge gas connector
material: stainless steel 6/4 mm or
1
4",
other options on request