Emerson Process Management HASX2E-IM-HS Carbon Monoxide Alarm User Manual


 
Emerson Process Management GmbH & Co. OHG TOC-3
X-STREAM X2
Instruction Manual
HASX2E-IM-HS
02/2012
TOC
Table of contents
Table of Contents
2.2.1 X-STREAM X2GK: ½19 Inch Table-Top Unit.................................2-5
2.2.2 X-STREAM X2GP: 19 Inch Table-Top and Rack-Mount Models ................2-12
2.2.3 X-STREAM X2XF: Single (XLF) or Dual (XXF) Compartment Field Housing .......2-15
2.2.4 X-STREAM X2FD: Flameproof Housing ...................................2-19
2.3 Information on Name Plate ..............................................2-22
Chapter 3 Measuring Principles 3-1
3.1 Infrared Measurement (IR), Ultraviolet Measurement (UV) .......................3-1
3.1.1 IntrinzX Technology ....................................................3-1
3.1.2 NDIR Detector ........................................................3-3
3.1.3 Technical Implementation ...............................................3-4
3.2 Oxygen Measurement ...................................................3-5
3.2.1 Paramagnetic Measurement .............................................3-5
3.2.2 Electrochemical Measurement ...........................................3-8
3.2.3 Electrochemical Trace Oxygen Measurement...............................3-11
3.3 Thermal Conductivity Measurement .......................................3-13
3.3.1 Principle of Operation .................................................3-13
3.3.2 Technical Implementation ..............................................3-14
3.4 Trace Moisture Measurement ............................................3-15
3.4.1 Special Operating Conditions ...........................................3-16
3.4.2 Accompanying Gases .................................................3-17
3.5 Measurement Specications .............................................3-19
Chapter 4 Installation 4-1
4.1 Scope of Supply........................................................4-1
4.2 Introduction ...........................................................4-2
4.3 Gas Conditioning .......................................................4-3
4.4 Gas Connections .......................................................4-5
4.5 Electrical Connections ...................................................4-7
4.6 Analyzer Specic Instructions for Installation..................................4-8
4.6.1 X-STREAM X2GK .....................................................4-9
4.6.2 X-STREAM X2GP ....................................................4-15
4.6.3 X-STREAM X2XF Field Housings (single XLF; Dual XXF) .....................4-23
4.7 Notes On Wiring Signal Inputs and Outputs .................................4-34
4.7.1 Electrical Shielding of Cables ...........................................4-34
4.7.2 Wiring Inductive Loads ................................................4-37
4.7.3 Driving High-Current Loads.............................................4-37
4.7.4 Driving Multiple Loads .................................................4-38
Chapter 5 Startup 5-1
5.1 Introduction ...........................................................5-1