Emerson Process Management HASX2E-IM-HS Carbon Monoxide Alarm User Manual


 
Emerson Process Management GmbH & Co. OHG 6-41
X-STREAM X2
Instruction Manual
HASX2E-IM-HS
02/2012
6
Software Menus
6.2 Menu System - IntSHS Menu
6.2.3.4.4 IntSHS Menu
Setup..
In/Outputs..
IntSHS..
Gas5: Sample
Gas6: V5
Gas7: V6
Gas8: V7
Page 2
Gas1: V1
Gas2: V2
Gas3: V3
Gas4: V4
Page 1
For an overview of all available options:
next page.
This menu congures the optional internal
components for routing gas (valves and
pumps) to be used in autocalibration proce-
dures.
Each available gas inlet ("Gas 1 ... Gas 8")
with a valve connected is assigned a virtual
valve label (V1...V8, Sample). (If the compo-
ents were installed in the factory, the basic
settings will already have been set).
These valves are then assigned a channel
and function (zero or span gas) in the VALVE
ASSIGNMENT MENU ( 6.2.3.2.2, page
6-26).
Note!
Depending on the model, 1 or 2 valve blocks
with up to 4 or 8 valves can be installed.
Note!
This menu appears only when the parameter
in the “Installed Options - Valves” is set to
Internal or IntExt (
6.2.3.5, page 6-43)
Pump1: Pump
Pump2: Off
Page 3
Additionally, the method used to control any
installed pumps can be set.
Note
Depending on the model, up to 2 pumps may
be installed.